    Server Room Cooling

    Server Room & Comms Room Cooling

    Comfort cooling and equipment cooling are different jobs. An office system is designed for people, runs in office hours, and is allowed to fail on a Sunday. A server room runs every hour of the year and fails expensively.

    What makes it different

    It never stops

    Equipment produces heat continuously, including at three in the morning in January when the office system is off. Server room cooling is specified to run all year, which changes the equipment and the controls.

    It has to cope in winter

    An outdoor unit is being asked to reject heat when it is below freezing outside. Ordinary comfort equipment is not always specified for that, and this is one of the most common reasons a comms room system fails in its first cold snap.

    Failure has a cost attached

    The question worth asking early is what happens to the business if the room gets hot. If the answer is serious, the system should be designed so that one failure does not stop the cooling — typically two units sharing the load, each able to hold the room alone, alternating so both stay exercised.

    Somebody needs to know before it is too late

    Temperature alarms matter as much as the equipment. A room that is quietly climbing at the weekend should be telling somebody.

    What we look at

    The heat output of the equipment in the room now and what is planned, the size and construction of the space, how air moves through the racks, where outdoor plant can go, the electrical supply, and what monitoring already exists. Small rooms are often worse than large ones, because a cupboard with a few servers in it has nowhere for the heat to go and is frequently ignored until something fails.

    What we install

    Systems specified for continuous operation and low outdoor temperatures, sized to the actual heat load rather than the room's floor area, with controls set for equipment rather than comfort. Where the room justifies it, two units in a duty and standby arrangement. And where it does not, we will say so rather than sell resilience you do not need.

    Maintenance is not optional here

    A comfort system that misses a service gets less efficient. A comms room system that misses a service eventually stops, and the cost of that is not the repair bill. These are the systems we most often recommend putting on a planned maintenance contract, and the ones where leak checking obligations are most likely to apply because they run hard all year.

    Common questions

    Sometimes, for a very small room, but comfort equipment is designed for office hours and mild weather. The two things that catch people out are continuous running and cold winter conditions, both of which need equipment specified for the job.

    It depends on what a failure would cost you. If the room going down stops the business, two units sharing the load — either able to hold the room alone — is the sensible answer. If it is a cupboard with a switch in it, it usually is not.

    With monitoring and an alarm that reaches somebody. It is worth as much as the cooling itself and it is often missing.

    Usually yes, but the route for pipework and where the outdoor unit goes become the deciding factors. That is what the survey establishes.

    More often than comfort cooling, because it runs continuously. These systems also frequently fall under refrigerant leak-checking rules.

    Yes. Work on a live server room is usually scheduled outside business hours by preference.

    Book a survey to protect your server room.

    Request a Quote
    HT Cooling Ltd

    Established air conditioning, refrigeration and HVAC contractors serving commercial, industrial and domestic clients across London and the Home Counties.

    Services

    Contact

    Accreditations

    F-Gas RegisteredConstructionline GoldAcclaim (SSIP)SMAS Worksafe

    © 2026 HT Cooling Ltd. All rights reserved.

    Office: Bourne Holdings, Broadway Road, Lightwater, Surrey GU18 5SH

    Registered in England and Wales. Company No. 13378090. VAT No. 382854660. Registered office: 7b Curley Hill Road, Lightwater, Surrey GU18 5YG.

    We use cookies for essential site functionality, and in future for analytics to improve our service. You can accept or reject non-essential cookies at any time. See our Privacy Policy for details.